Arq. bras. oftalmol ; 79(4): 264-267, July-Aug. 2016. graf
Artigo em Inglês | LILACS | ID: lil-794574

RESUMO

ABSTRACT We report two cases of suspicious asymmetric bow tie and inferior steepening on topographic evaluations with reflection (Placido) and projection (Scheimpflug). Rotating Scheimpflug corneal and anterior segment tomography (Oculus Pentacam HR, Wetzlar, Germany)® was performed in the first case, with a maximal keratometric value (Kmax) of 43.2 D and an overall deviation value from the Belin/Ambrósio Enhanced Ectasia Display (BAD-D) of 1.76, which was observed in the study eye (OD). BAD-D was 6.59 in the fellow eye, which had clinical findings that were consistent with keratoconus stage 2. The second case presented with a Kmax of 45.3 D and BAD-D of 0.76 in OD and 1.01 in OS. This patient had discontinued wearing soft contact lens less than 1 day prior to examination. Corneal tomographic data enabled us to distinguish mild or forme fruste keratoconus from contact lens-induced corneal warpage, and similar findings were observed on curvature maps.


RESUMO O presente estudo tem por objetivo relatar dois casos suspeitos que apresentam bow tie assimétrico e encurvamento inferior nas avaliações topográficas de reflexão (Placido) e projeção (Scheimpflug). A tomografia de córnea e segmento anterior com o sistema Scheimpflug (Oculus Pentacam HR, Wetzlar, Alemanha)® mostrou no primeiro caso, a ceratometria máxima (Kmax) de 43,2 D e o valor D no Belin/Ambrósio Enhanced Ectasia Display (BAD-D) de 1,76 no olho estudado (OD). O olho contralateral apresentava BAD-D de 6,59 e achados clínicos compatíveis com ceratocone (KC) grau 2. O segundo caso apresentava Kmax de 45,3 D e BAD-D de 0,76 em OD e 1,01 em OS. Este paciente havia interrompido o uso de lentes de contato gelatinosas 1 dia antes do exame. A avaliação tomográfica avançada nos permitiu distinguir ceratocone leve ou subclínico de warpage induzido por lentes de contato, enquanto resultados semelhantes foram observados em mapas de curvatura anterior.


Assuntos
Humanos , Masculino , Feminino , Adulto , Lentes de Contato Hidrofílicas/efeitos adversos , Topografia da Córnea/métodos , Ceratocone/patologia , Ceratocone/diagnóstico por imagem , Valores de Referência , Índice de Gravidade de Doença , Diagnóstico Diferencial , Dilatação Patológica/etiologia , Ceratocone/etiologia
2.
Rev. bras. oftalmol ; 73(2): 75-80, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-718436

RESUMO

Purpose: To compare the ability to detect preoperative ectasia risk among LASIK candidates using classic ERSS (Ectasia Risk Score System) and Pentacam Belin-Ambrósio deviation index (BAD-D), and to test the benefit of a combined approach including BAD-D and clinical data. Methods: A retrospective nonrandomized study involved preoperative LASIK data from 23 post-LASIK ectasia cases and 266 stable-LASIK (follow up > 12 months). Preoperative clinical and Pentacam (Oculus; Wetzlar, Germany) data were obtained from all cases. Mann-Whitney's test was performed to assess differences between groups. Stepwise logistic regression was used for combining parameters.The areas under the Receiver Operating Characteristic (ROC) curves (AUC) were calculated for all parameters and combinations, with pairwise comparisons of AUC (DeLong's method). Results: Statistically significant differences were found for age, residual stromal bed (RSB), central corneal thickness and BAD-D (p<0.001), but not for sphere, cylinder or spherical equivalent (p>0.05). ERSS was 3 or more on 12/23 eyes from the ectasia group (sensitivity = 52.17%) and 48/266 eyes from the stable LASIK group (18% false positive). BAD-D had AUC of 0.931 (95% CI: 0.895 to 0.957), with cut-off of 1.29 (sensitivity = 87%; specificity = 92.1%). Formula combining BAD-D, age and RSB provided 100% sensitivity and 94% specificity, with better AUC (0.989; 95% CI: 0.969 to 0.998) than all individual parameters (p>0.001). Conclusion: BAD-D is more accurate than ERSS. Combining clinical data and BAD-D improved ectasia susceptibility screening. Further validation is necessary. Novel combined functions using other topometric and tomographic parameters should be tested to further enhance accuracy. .


Objetivo: Comparar a capacidade de detectar risco de ectasia no pré-operatório de LASIK usando o clássico ERSS (Ectasia Risk Score System) e índice Belin- Ambrósio (BAD- D) do Pentacam; e para testar o benefício de uma abordagem combinada, incluindo BAD-D e dados clínicos. Métodos: Estudo não randomizado retrospectivo envolveu dados pré-operatórios de LASIK de 23 casos que evoluíram para ectasia pós-LASIK e 266 casos estáveis após LASIK com acompanhamento mínimo de 12 meses. Dados préoperatórios clínicos e do Pentacam (Oculus, Wetzlar, Alemanha) foram obtidos para todos os casos. O teste de Mann-Whitney foi realizado para avaliar as diferenças entre grupos. Regressão logística foi utilizada para combinar parâmetros. As áreas sob as curvas Receiver Operating Characteristic (ROC; AUC) foram calculadas para todos os parâmetros e as combinações. Comparações de pares das AUC foram realizadas com método de DeLong. Resultados: Foram encontradas diferenças estatisticamente significativas para a idade, residual leito estromal (RSB), espessura corneana central e BAD- D (p <0,001), mas não para a grau esférico, cilindro ou equivalente esférico (p > 0,05). ERSS foi de três ou mais em 12/23 olhos do grupo ectasia (sensibilidade = 52,17 %) e 48/ 266 olhos do grupo LASIK estável (18% falso positivo). BAD- D teve AUC de 0,931 (IC 95%: 0,895-0,957), com corte de 1,29 (sensibilidade=87%, especificidade=92,1%). A fórmula que combinou BAD-D, idade e RSB, gerou 100% de sensibilidade e especificidade de 94%, com melhor AUC (0,989, IC 95%: 0,969-0,998) do que todos os parâmetros individuais (p>0,001). Conclusão: BAD-D é mais preciso do que ERSS. Combinações de dados clínicos e os BAD-D melhorou a capacidade de identificação ...


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Técnicas de Diagnóstico Oftalmológico/normas , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Curva ROC , Medição de Risco , Córnea/cirurgia , Córnea/patologia , Topografia da Córnea
3.
Rev. bras. oftalmol ; 73(1): 16-22, Jan-Feb/2014. tab, graf
Artigo em Português | LILACS | ID: lil-712769

RESUMO

A bioestatística ganha crescente importância e relevância nos últimos anos, sendo um dos principais pilares da investigação científica. Possui uma série de conceitos e regras que devem ser bem compreendidos para se realizar ou analisar um artigo. Nesta revisão são abordadas algumas das principais ferramentas utilizadas nos trabalhos de interesse da área oftalmológica, suas aplicações e limitações.


The biostatistics has gained significant importance in recent years, being one of the mainstays of current scientific research. It has a series of concepts and rules that must be understood to carry out or analyze an article. In this review we will discuss some of main tools utilized in works of interest in ophthalmology, its applications and limitations.


Assuntos
Bioestatística , Estatística como Assunto/métodos , Interpretação Estatística de Dados , Tamanho da Amostra
4.
Rev. bras. oftalmol ; 71(5): 317-321, set.-out. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-654992

RESUMO

OBJETIVO: Avaliar e comparar as alterações biomecânicas da córnea por meio do Ocular Response Analyzer® (ORA Reichert Ophtalmics Instruments, Buffalo, New York, USA) antes e após Lasik com Moriá ® Sub Bowman Keratomileusis (SBK) One Use Plus (OUP) em pacientes míopes e hipermetrópes. MÉTODOS: Foram estudados 33 olhos, sendo 19 olhos míopes e 14 olhos hipermetrópes submetidos à cirurgia refrativa com técnica Lasik com flap fino (100 µ) utilizando Moriá SBK OUP. O ORA foi realizado no pré-operatório e 1 mês após a cirurgia para avaliar a biomecânica da córnea. O CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (goldmann gold standard, Goldmann correlated intraocular pressure) a IOPcc (corneal compensated intraocular pressure) e mais 38 variáveis biomecânicas da córnea derivadas do sinal de resposta foram avaliados. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. O teste de Wilcoxon foi utilizado para comparar as variáveis antes e após a cirurgia para cada grupo. As diferenças entre as medidas pré e pós-operatórias dos olhos míopes foram comparadas com as diferenças obtidas nos olhos hipermetrópes, utilizando-se o teste de Mann-Whitney. Foi considerado como estatisticamente significante p < 0,05%. RESULTADOS: Houve diferença significativa antes e após Lasik em olhos míopes e hipermetrópes na variável IOPg(Wilcoxon, p <0,05), porém não houve em IOPcc. Somente em olhos míopes houve diferenças significativas em CH e CRF, antes e após Lasik com Moriá SBK OUP, como também 9 parâmetros derivados do ORA Waveform_Sinal Gráfico (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0,05). Em olhos hipermetrópes houve diferenças antes e após Lasik das seguintes variáveis: aspect2, h2, dive2, mslew2 e H21 (Wilcoxon p<0,05).Diferenças nas variáveis IOPg e p1area, antes e após Lasik foram maiores em olhos míopes do que hipermetrópes (Mann-Whitey, p <0.05). CONCLUSÃO: Existem alterações das propriedades biomecânicas da córnea após Lasik com Moriá SBK OUP. Em geral, o impacto da biomecânica da córnea após Lasik em olhos míopes é maior do que em olhos hipermetrópes. As mudanças das variáveis relacionadas ao primeiro pico de aplanação (ORA waveform) são mais vistos em olhos míopes e as relacionadas ao segundo pico de aplanação em olhos hipermetrópes.


PURPOSE: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer®; Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. METHODS: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis - One Use Plus, Moria®).CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. RESULTS: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p <0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0, 05), 8 of these being related to the first sign of flattening.Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05).There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p <0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p <0.05). CONCLUSION: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.


Assuntos
Humanos , Córnea/fisiologia , Técnicas de Diagnóstico Oftalmológico , Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia/cirurgia , Fenômenos Biomecânicos/fisiologia , Estudos Observacionais como Assunto , Estudos Prospectivos